News

Deterministic and cycle-accurate: Data acquisition from optimized data blocks

ibaPDA v8.3 supports S7 request with optimized data blocks and ibaNet-E


Cycle-accurate data acquisition from S7 controllers with optimized data blocks in ibaPDA: With version 8.3 of ibaPDA, process values from optimized data blocks can now be acquired cycle-accurately. Since firmware 3 and TIA Portal V18, S7 controllers offer users the the long-awaited possibility to acquire data from optimized data blocks. This means that the data blocks are no longer addressed via the operand address, but exclusively via their variable names. Since the PLC manages the internal memory itself in this case, access is much faster. With the extension of the S7 request function blocks in ibaPDA, iba AG reacts to this update and thus allows the signal acquisition from optimized blocks - directly and with cycle accuracy. The creation or adaptation of separate DBs is thus not necessary, even in the environment of optimized data blocks. Thus, ibaPDA enables both request functions: those that support optimized data blocks and those that do not.

Improved data transfer without additional hardware

With version 8.3, the S7 request in ibaPDA can also be realized with the deterministic network protocol ibaNet-E. In this case, the request blocks configured in ibaPDA are sent by the controller in a defined clock frequency via the iba-specific network protocol. Since the amount of data transmitted here is lower than with the standard protocols due to the buffered transmission, the risk of data collision and network jitter is significantly reduced. In this way, the data acquisition with ibaPDA can be done deterministically and the quality of the acquired data increases. Since the ibaNet-E protocol can be realized via a standard network card, users do not have to install any additional hardware - thus, the operation of ibaPDA on virtual machines is also supported.


|Products
Stay up-to-date with iba!

Subscribe to regular product information.

Read more


iba QuickSupport

If needed - and technically possible on your side - our engineers can initiate a TeamViewer® session to view or access your system.

Download

Get in touch with us

隐私保护

通过选择一个国家,我的请求将被转发给iba AG负责销售和支持的国家分支机构。

Support hotline

For urgent matters, please contact the support hotline of your local sales partner.